← Sweden Pack reference
Sweden Pack · model hub

Every Sweden Pack element and its model entry

Start from the element in front of you — a wall, a doorset, a slab — and read where it appears in Revit and IFC, which CoClass table and BK04 level it is normally designated in, what quantity it is resolved by, and where it enters a decision chain.

12 elements · reviewed

12 of 12 shown

External wall

Yttervägg

A climate-separating wall: the build-up, not the finish, decides almost everything downstream.

IFC
IfcWall / IfcWallStandardCase, typed by IfcWallType
Qty
Net area (m²) per layer, taken from the exact extracted model version

Internal wall

Innervägg

A separating wall inside the climate shell: sound and fire requirements usually govern, not weather.

IFC
IfcWall typed by IfcWallType
Qty
Net area (m²) per layer

Door

Dörr

A hosted opening element whose decision usually splits into leaf, frame and hardware set.

IFC
IfcDoor typed by IfcDoorType, with IfcDoorLiningProperties and IfcDoorPanelProperties
Qty
Each (count) per doorset

Window

Fönster

A hosted opening element where glazing, frame and installation are governed separately.

IFC
IfcWindow typed by IfcWindowType, with IfcWindowLiningProperties and IfcWindowPanelProperties
Qty
Each (count)

Floor / slab

Bjälklag

A horizontal structural and separating element, usually the largest single carbon item in a building.

IFC
IfcSlab typed by IfcSlabType, PredefinedType FLOOR or BASESLAB
Qty
Area (m²) per layer and volume (m³) for cast layers, from the extracted model version

Roof

Tak

A climate-separating upper enclosure where the layer sequence, not the shape, drives requirements.

IFC
IfcRoof, with slab components typed by IfcSlabType, PredefinedType ROOF
Qty
Sloped area (m²) per layer

Ceiling

Undertak

A finishing and often acoustic system suspended below the structure, governed by the space it serves.

IFC
IfcCovering typed by IfcCoveringType, PredefinedType CEILING
Qty
Area (m²)

Column

Pelare

A vertical carrying member; architectural and structural columns are separate identities.

IFC
IfcColumn typed by IfcColumnType
Qty
Volume (m³) or mass (kg) for structural members

Beam / structural framing

Balk

A horizontal carrying member, usually resolved by profile and length.

IFC
IfcBeam typed by IfcBeamType
Qty
Length (m) with a governed profile

Stair

Trappa

A circulation assembly where regulation, not the model, sets most of the binding requirements.

IFC
IfcStair with IfcStairFlight components, typed by IfcStairType
Qty
Each (count) per flight or per stair

Railing / balustrade

Räcke

A safety element resolved by linear metre and by tested load capacity.

IFC
IfcRailing typed by IfcRailingType
Qty
Length (m)

Curtain wall

Glasfasad

A glazed facade system resolved at system level — its mullions and panels are not stand-alone walls.

IFC
IfcCurtainWall typed by IfcCurtainWallType, with IfcPlate and IfcMember components
Qty
Facade area (m²) at system level