Every Sweden Pack element and its model entry
Start from the element in front of you — a wall, a doorset, a slab — and read where it appears in Revit and IFC, which CoClass table and BK04 level it is normally designated in, what quantity it is resolved by, and where it enters a decision chain.
12 of 12 shown
External wall
YtterväggA climate-separating wall: the build-up, not the finish, decides almost everything downstream.
- IFC
- IfcWall / IfcWallStandardCase, typed by IfcWallType
- Qty
- Net area (m²) per layer, taken from the exact extracted model version
Internal wall
InnerväggA separating wall inside the climate shell: sound and fire requirements usually govern, not weather.
- IFC
- IfcWall typed by IfcWallType
- Qty
- Net area (m²) per layer
Door
DörrA hosted opening element whose decision usually splits into leaf, frame and hardware set.
- IFC
- IfcDoor typed by IfcDoorType, with IfcDoorLiningProperties and IfcDoorPanelProperties
- Qty
- Each (count) per doorset
Window
FönsterA hosted opening element where glazing, frame and installation are governed separately.
- IFC
- IfcWindow typed by IfcWindowType, with IfcWindowLiningProperties and IfcWindowPanelProperties
- Qty
- Each (count)
Floor / slab
BjälklagA horizontal structural and separating element, usually the largest single carbon item in a building.
- IFC
- IfcSlab typed by IfcSlabType, PredefinedType FLOOR or BASESLAB
- Qty
- Area (m²) per layer and volume (m³) for cast layers, from the extracted model version
Roof
TakA climate-separating upper enclosure where the layer sequence, not the shape, drives requirements.
- IFC
- IfcRoof, with slab components typed by IfcSlabType, PredefinedType ROOF
- Qty
- Sloped area (m²) per layer
Ceiling
UndertakA finishing and often acoustic system suspended below the structure, governed by the space it serves.
- IFC
- IfcCovering typed by IfcCoveringType, PredefinedType CEILING
- Qty
- Area (m²)
Column
PelareA vertical carrying member; architectural and structural columns are separate identities.
- IFC
- IfcColumn typed by IfcColumnType
- Qty
- Volume (m³) or mass (kg) for structural members
Beam / structural framing
BalkA horizontal carrying member, usually resolved by profile and length.
- IFC
- IfcBeam typed by IfcBeamType
- Qty
- Length (m) with a governed profile
Stair
TrappaA circulation assembly where regulation, not the model, sets most of the binding requirements.
- IFC
- IfcStair with IfcStairFlight components, typed by IfcStairType
- Qty
- Each (count) per flight or per stair
Railing / balustrade
RäckeA safety element resolved by linear metre and by tested load capacity.
- IFC
- IfcRailing typed by IfcRailingType
- Qty
- Length (m)
Curtain wall
GlasfasadA glazed facade system resolved at system level — its mullions and panels are not stand-alone walls.
- IFC
- IfcCurtainWall typed by IfcCurtainWallType, with IfcPlate and IfcMember components
- Qty
- Facade area (m²) at system level